- - Operating frequencies are below 6 GHz.
- - The same power levels and tune-up tolerances apply for both body and limb use cases.
The RF exposure technical brief must include a description showing compliance with all conditions above.
Exceptions (when reduction is not allowed)
The 0 mm limb SAR test reduction cannot be applied to:
- - Hand exposure during next-to-head voice calls per section 5.10 of RSS-102.SAR.MEAS.
- - Frequencies above 6 GHz that are evaluated under absorbed power density (APD) limits.
- - Verify test configurations meet the stated conditions before omitting 0 mm limb SAR tests.
- - Update RF exposure briefs to include justification for any applied test reduction.
- - Continue full testing for head and >6 GHz exposure scenarios.
Eleos Compliance offer international RF, EMC, Safety and Green type approval services for radiocommunications products. Eleos Compliance are a sustainable, values-based business combining extensive experience in the wireless homologation sector with outstanding project management. For full support with your global market access requirements or regulatory intelligence needs please contact us at enquiries@eleoscompliance.com